Gear · Certified Metrology

Praxis Instruments Praxis Seal Integrity Tester Collar Kit

₡540

ManufacturerPraxis InstrumentsVisibility: public
FamilySeal Integrity TestersVisibility: public · Carried Load Mode: FULL · Measurement Status: ESTIMATED
ModelPraxis Seal Integrity TesterMass Kg: 2.4 · Tradeoff: Dirty frost or grease lies; a forged or overdue certificate turns a precise tool into liability theater. · Visibility: public
VariantCollar KitMass Kg: 2.4 · Tradeoff: Dirty frost or grease lies; a forged or overdue certificate turns a precise tool into liability theater. · Buyer Problem: Crews need proof a seal holds before a suit, hatch, hose, or cargo lid becomes an argument wi
Physical mass
2.4 kg
Stowed volume
0.006 m³
Measurement
estimated
Damage resistance
DR 0 (estimated)

Rules-ready

3D6 Stats

Weight, damage resistance, advantages, disadvantages, and skill bonuses
Weight2.4 kg (5.3 lb)
DR0
AdvantagesNone
DisadvantagesNone
Skill bonusesUses Electronics Operation (Sensors)

A compact tester with collars for suit rings, hatches, hose couplings, and cargo lids. It applies a controlled pressure pulse and listens for leakage too small to hear over ship noise. Frost and old lubricant skew readings unless cleaned first. The device prints a signed pass tag, which turns a technical judgment into paperwork somebody may later try to edit. Praxis recommends a bench check after hard use; skipped certificates are cheap until an insurer asks for the last valid one. Resale value lives in its reference history, not its casing. One missing calibration turns precise measurements into expensive suggestions.

buyer Problem: Crews need proof a seal holds before a suit, hatch, hose, or cargo lid becomes an argument with vacuum or an insurer.; calibration Minutes: 10; carried Load Mode: FULL; compatibility: Included collars cover suits, doors, and hoses; improvised adapters work at a penalty.; failure Consequence: Inconclusive results waste time; critical failure prints a false pass that can kill people later.; logistical Burden: One hundred fifty tests per charge, monthly calibration supplies, certificate custody, and collar cleaning.; maintenance Interval Days: 30; maintenance Reality: Clean collars before use, bench-check after hard use, and recalibrate with the reference collar every 30 days.; mass Kg: 2.4; measurement Status: ESTIMATED; signature Capability: Thirty-second pressure-pulse leak test with signed pass tags across suit, door, and hose collars.; test Charge Capacity: 150; test Time Seconds: 30; tradeoff: Dirty frost or grease lies; a forged or overdue certificate turns a precise tool into liability theater.; volume Liters: 5.5

Same model, different hardware

Variants and retailer offers

Collar Kit

Mass Kg: 2.4 · Tradeoff: Dirty frost or grease lies; a forged or overdue certificate turns a precise tool into liability theater. · Buyer Problem: Crews need proof a seal holds before a suit, hatch, hose, or cargo lid becomes an argument wi

Mass Kg
2.4
Tradeoff
Dirty frost or grease lies; a forged or overdue certificate turns a precise tool into liability theater.
Buyer Problem
Crews need proof a seal holds before a suit, hatch, hose, or cargo lid becomes an argument with vacuum or an insurer.
Volume Liters
5.5
Compatibility
Included collars cover suits, doors, and hoses; improvised adapters work at a penalty.
Carried Load Mode
FULL
Test Time Seconds
30
Logistical Burden
One hundred fifty tests per charge, monthly calibration supplies, certificate custody, and collar cleaning.
Measurement Status
ESTIMATED
Calibration Minutes
10
Failure Consequence
Inconclusive results waste time; critical failure prints a false pass that can kill people later.
Maintenance Reality
Clean collars before use, bench-check after hard use, and recalibrate with the reference collar every 30 days.
Test Charge Capacity
150
Signature Capability
Thirty-second pressure-pulse leak test with signed pass tags across suit, door, and hose collars.
Maintenance Interval Days
30

Retailer offers

KHES